Full Product Manual
17
Load Mode Options
1 2 3 4
Programming Load Terminal
1. This screen is displaying the current Load Mode.
2. To enter screen 2 press and hold t
he Enter button. This screen will allow you to change
the load mode.
3. To change the load mode press the up or down button.
4.
Once you have selected the desired load mode press the Enter button to save the setting.
5. To exit the programming setting press the left button.
Setting Mode Description
0 Automatic(On/Off)
Time control
15 Manual
16 Test
17
24Hr
The load will turn on at night when the solar
panel is no longer producing any power after
a short time delay. The load will turn off
when the panel starts producing power.
When the panel is no longer producing power
the load will be ON for 1-14 hours or until the
panel starts producing power.
Used to troubleshoot load terminal (No
Time Delay). When voltage is detected
load will be off and when no voltage is
detected load will be on.
In this mode, the user can turn the Load
On/Off by pressing the Enter button at
any time.
The load will be on for 24 hours a day.
1-14