Full Product Manual

15
Change the Parameters
Simply hold the “ENTER” button for approximately 5 seconds until the display flashes. Once
flashing, then press “SELECT” until the desired parameter is reached and press “ENTER” one
more time to lock in the parameter.
NOTE: The screen must be at the appropriate interface in order to change the specific
parameter.
1. Power Generation Interface Reset
The user is able to reset the current power generation (kWh) back to 0 kWh.
2. Battery Interface Set Battery Type
In this interface, the user is able to select which type of battery is connected to the charge
controller. Choose from Sealed, Gel, Flooded or Lithium batteries.
3. Battery Temperature Interface Change from C° to F°
The user can select between displaying battery temperature in Celsius or Fahrenheit.
4. Set Battery Type to LithiumSet Lithium Battery Parameters
When using the Adventurer to charge lithium battery, the user is able to set Battery
Parameters. In the Battery Interface, select Lithium as Battery Type. Short press “ENTER” to
enter Battery Voltage selection interface.
Press “SELECT” to select the Battery Voltage. Press “ENTER” to confirm selection and go to
Charging Parameters Interface.
Press “SELECT” to change the Boost Voltage. The default setting is 14.2V and the user is
able to set it in the range 12.6~16.0V, with a step of 0.2V. Hold “ENTER” to confirm the
selection. The setting will also be automatically saved after 15 seconds without holding
“ENTER”.