BATTERY POWER INVERTERS 12V Pure Sine Wave Inverter Manual 2000w Version 1.
Important Safety Instructions Please save these instructions. This manual contains important safety, installation, and operating instructions for the inverter. The following symbols are used throughout the manual: WARNING CAUTION NOTE Indicates a potentially dangerous condition. Use extreme caution when performing this task. Indicates a critical procedure for safe and proper operation of the inverter. Indicates a procedure or function that is important to the safe and proper operation of the inverter.
NEVER connect the AC output of the unit directly to an Electrical Breaker Panel/ Load Centre which is also fed from the utility power / generator. When connecting battery terminals, ensure the polarity of the battery connections is correct. Incorrect polarity may cause permanent damage to the unit. Be careful when touching bare terminals of capacitors as they may retain high lethal voltages even after power is removed.
Table of Contents General Information 04 Included Components 05 Identification of Parts (AC Side) 06 Identification of Parts (DC Side) 07 Installation 08 Location Recommendations 08 Sizing a Battery Bank 09 Grounding 10 DC Side Connection 10 Operation 03 12 AC Side Operation 12 Eco Power Saving Mode Instruction 12 Inverter Troubleshooting 12 Specifications 13 Dimensions 14
General Information The Renogy Pure Sine Wave Power Inverter delivers superior performance for remote off-grid applications, capable of producing cleaner, smoother, and more reliable electricity for a user’s electronic needs.
Included Components The Renogy Pure Sine Wave Battery Inverters will be shipped with inverter cables and a remote control for powering the inverter on or off. Inverter Model Gauge 2000W 4AWG*2 2FT Wired remote control 05 List dimensions 2.88 x 2.31 x .94in / 73 x 58.7 x 23mm Thickness 0.63in / 1.5mm Wire length Approx 19.
Identification of Parts (AC Side) 1 5 2 3 4 9 8 Figure 2: 2000W Inverter 7 6 Key Parts 1. High Output AC Terminals — These terminals are for connecting 110 Volt A C devices that require more than 15 amps to operate or for connection to distributed wiring that has multiple AC outlets. Remove the two screws on protective cover to access the terminals. Any AC output wiring that is directly connected must comply with US National Electric Code (NEC) wiring gauge recommendations.
3. Fault LED (Red) — The red indicator turns on as the inverter shuts down due to overheating, overload, under voltage, or over voltage. Immediately turn off all AC appliances if the Fault LED is lit. Allow the inverter to cool before restart. Make sure that the ventilation vents are not blocked. If an inverter shutdown was preceded by a buzzing sound, there may be an excessive load in combination with low voltage or a cable problem. 4. ON/OFF Switch — Controls AC output. 5.
Installation WARNING CAUTION CAUTION Make sure inverter is in the off position before connecting anything. Do not over-torque or over tighten the terminals. This could potentially damage the unit. Refer to the technical specifications for max wire sizes on the controller and for the maximum amperage going through wires. Location Recommendations WARNING Never install the inverter in a sealed enclosure with flooded batteries. Gas can accumulate and there is a risk of explosion.
Sizing a Battery Bank Determine the amount of Watts (Amps * Volts) for the load, and how long the load needs to operate—each electrical appliance has technical specifications indicating the watts, or the volts and amps required for operation. Estimate load run-time—Battery size depends on load watts and run-time. Most loads are not constant, so estimation is very important.
Grounding The Renogy Pure Sine Wave inverters come equipped with a grounding lug to appropriately ground to earth or to another designated ground (for example, a metal frame of an RV). The connections to ground must be tight and against bare metal. Whether using the inverter in a mobile application, such as an RV, or in a building, grounding is highly recommended. The recommended wire size for grounding is 10 AWG insulated copper strand wire.
1.Flip inverter power to OFF position (on AC side) 11 2.Remove Cap, then unscrew inverter terminals and connect battery connections. Then tighten.
Operation Assuming proper battery connection, the inverter is now ready for use. AC Side Operation 1.Connect electronic devices to electrical socket (s) on inverter. Flip inverter power to ON position (on AC side) 2. When finished, switch AC devices off FIRST, then turn off inverter switch CAUTION CAUTION Avoid switching on the inverter with the load (electronic devices) already switched on. This may trigger an overload since some electronic devices have an initial high power surge to start.
Specifications Model R-INVT-PGH1-20111S-G1 Continuous Power Input Voltage Output Voltage Peak surge Efficiency Frequency 2000 W 12V DC 110V AC +/-10% 4000 W > 90% 50Hz/60Hz No load current draw < 2.0A Low voltage alarm Low voltage shutdown Over voltage alarm Over voltage shutdown Cooling fan AC output sockets Power output control Dimensions Net weight (approximate) Certification 10.5V ± 0.5V DC 10.0V ± 0.5V DC 15V±0.5V DC 16V ± 0.5V DC Thermally controlled 2 AC On/Off Switch 15.80 x 9.80 x 3.
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
RENOGY.COM Renogy reserves the right to change the contents of this manual without notice. US 2775 E Philadelphia St, Ontario, CA 91761, USA 909-287-7111 www.renogy.com customerservice@renogy.com CN 苏州高新区科技城培源路1号5号楼-4 JP https://www.renogy.jp onlinestorejp@renogy.com CA https://ca.renogy.com onlinestoreca@renogy.com AU https://au.renogy.com onlinestoreau@renogy.com UK https://uk.renogy.com onlinestoreuk@renogy.com DE https://de.renogy.com onlinestorede@renogy.com FR https://fr.renogy.