Replacement Part List

21
The inverter is only
able to run AC loads
for a short period of
time
This will happen when the battery voltage is low. Check
battery voltage and resume running loads when battery
voltage is above 12.7 volts.
External Fusing
Fusing is a recommended in electrical systems to provide a safety measure for
connections going from battery to inverter charger. Always use the recommended wire
gauge size based on the rated power of the inverter charger.
NEC Maximum Current for different Copper Wire Sizes
#AWG
16
14
12
10
8
6
4
2
0
2/0
3/0
4/0
Max.
Current
10A
15A
20A
30A
55A
75A
95A
130A
170A
195A
225A
260A
Technical Specifications
Model
RNG-INVT-1000-12V-C
RNG-INVT-2000-12V-C
RNG-INVT-3000-12V-C
Rated Power
1000W
2000W
3000W
Surge Power
2000W
4000W
6000W
Rated Voltage
12V
Rated Voltage Range
10V-16V
Input Voltage
DC ≥ 10V ± 0.5V
Over-Voltage Range
16V ± 0.5V
Low Battery Voltage Alarm
10.5V/11.0V
Output Waveform
Pure Sine Wave
Nominal Efficiency
>88% Peak
Power Factor
0.9-1.0
Nominal Output Voltage
100-110-120VAC
Output Voltage Regulation
±10% RMS
Output Frequency
50/60Hz ±0.3Hz
THD
<10%
Input Voltage Waveform
Sine Wave (External AC Source)
AC Input Range
90-135 VAC
AC Input Frequency
Range
57-65±0.3Hz for 60Hz