Full Product Manual

16
In Light On/Off, the user sets parameters to turn the
load on or off.
The load terminal automatically turns on when the
solar voltage goes BELOW the point of NTTV (Night
Time Threshold Voltage).The load automatically turns
off when the voltage goes ABOVE the point of DTTV
(Day Time Threshold Voltage). There is a delay
between turning the load on or off and can be
programmed to be from 0-99minutes.
NOTE: Minimum and maximum charge parameter
values can be found in Technical Specifications
Similar to Light On/Off parameter with the addition of
a timer that the user sets in order to indicate how long
a load will be on or off. The user also sets an
appropriate time for when it is night time.
NOTE: Timer needs to be activated for it to work.
Using a 24-hour clock, the user is able to set the time
for when the load will turn on and the time for when
the load will turn off.
5. Rated Value
Use to cycle through the screens. Press to select
NOTE: To customize charge parameters, BATT must be set to USER
For BATT: the user selects which battery describes
the one they have12V, 24V, or AUTO
For Type: The user chooses from Gel, Sealed,
Flooded or USER
The user is able to modify the Amp-hours (AH) to
reflect the actual battery capacity.
NOTE: The Load and PV options will not be adjustable
since the value is based on the charge controller.
Time Control 1
On Time: 19:00:00
Off Time: 06:00:00
Light On + Timer
On: 05.0V Delay: 10m
Off: 06.0V Delay: 10m
Night Time: 12:00
Light On/Off
On: 05.0V Delay: 10m
Off: 06.0V Delay: 10m
Manual
Light On/Off
Light On+Timer
Time
Rated Value
Batt: AUTO 0200AH
Load: 20.0A PV:20.0A
Type: Seal
ENTER/
/ -
/