User manual

55
InstallationoftheZ-limitswitch
1x limit switch holder plate with limit switch
4x cylinder head screw M5x8 black
2x slot nut M5
Pushthe2slotnutsintothelowerslotoftheupperaluminiumprole
attherearasshowninthegure.
The threads must both point outwards.
Align the two slot nuts with the hole distance of the end switch holding
plate.
Attach the limit switch holding plate to the two slot nuts placed before
loosely with the two M5 cylinder-head screws.
The unit must be aligned so that the button on the PCB points down.
Move the table all the way up by turning the spindle.
Align the limit switch holding plate so that the button is pushed by the
hexagonsocketinthelefttabletappet(viewedfromthefront).
Move the table a little down again and tighten the two M5-screws.