Instructions

p) LED indicators
The keypad LED turns on when the keypad is in standby. The LED can be disabled if you do not
wantittostayswitchedon(e.g.ifyounditdisturbingatnight).
Program code Function Conrm
8 4 0 or 1 #
Options
0 The LED is switched off in standby mode.
1 The LED turns on when the keypad is in standby.
q) Door open delay
Access to buildings or rooms can be controlled with user codes. To leave a room or building,
press the door release button. You can set a delay interval after the button is pressed to delay
the door release/output 1. This may be necessary in hospitals or kindergartens to prevent pa-
tients/children from leaving a protected area. The code lock will beep when the door release
button is pressed.
These settings do not affect the functionality of the keypad. They are optional features
andmustbeconguredbytheowner.
Program code Function Conrm
8 5 0 or 4 #
Options
0 Press the button to open the door. Output 1 is immediately enabled without an acoustic warn-
ing or delay (default setting)
1 Press the button to open the door. The keypad will beep for 5 seconds before output 1 is
enabled.
2 Press the button to open the door. The keypad will beep for 10 seconds before output 1 is
enabled.
3 Press and hold the door release button for 5 seconds. The keypad will beep for 5 seconds
before output 1 is enabled.
4 Press and hold the door release button for 10 seconds. The keypad will beep for 10 seconds
before output 1 is enabled.
36