Instructions
p) LED indicators
The keypad LED turns on when the keypad is in standby. The LED can be disabled if you do not
wantittostayswitchedon(e.g.ifyounditdisturbingatnight).
Program code Function Conrm
8 4 0 or 1 #
Options
0 The LED is switched off in standby mode.
1 The LED turns on when the keypad is in standby.
q) Door open delay
Access to buildings or rooms can be controlled with user codes. To leave a room or building,
press the door release button. You can set a delay interval after the button is pressed to delay
the door release/output 1. This may be necessary in hospitals or kindergartens to prevent pa-
tients/children from leaving a protected area. The code lock will beep when the door release
button is pressed.
These settings do not affect the functionality of the keypad. They are optional features
andmustbeconguredbytheowner.
Program code Function Conrm
8 5 0 or 4 #
Options
0 Press the button to open the door. Output 1 is immediately enabled without an acoustic warn-
ing or delay (default setting)
1 Press the button to open the door. The keypad will beep for 5 seconds before output 1 is
enabled.
2 Press the button to open the door. The keypad will beep for 10 seconds before output 1 is
enabled.
3 Press and hold the door release button for 5 seconds. The keypad will beep for 5 seconds
before output 1 is enabled.
4 Press and hold the door release button for 10 seconds. The keypad will beep for 10 seconds
before output 1 is enabled.
36