Settings on the ceiling-mounted motion detector
Only use the motion detector with the cover in place! Contact with electrically live
parts (cable or screws of the screw terminal) may cause life-threatening injury due
to electric shock!
a) Dial „TIME“ (power-up time)
Using this control dial, you can set the power-up time for the output L´ to the connected
device.
Turning it to the left will reduce the power-up time of the connected device, while turning to
the right will extend the time.
If new motion is detected during the on-time, the on-time duration starts once again, and the
consumer stays switched on.
b) Dial „LUX“ (brightness setting)
This control knob allows the switching threshold to be set, i.e. the ambient brightness at
which the ceiling-mounted motion detector is activated.
Turning the dial counter-clockwise to the left means the ceiling-mounted motion detector
will activate when it is darker; turning it to the right clockwise (in direction of the sun symbol)
activates the motion detector in brighter conditions.
The brightness sensor is hidden beneath the round diffusion panel of the PIR sen-
sor.
Functional test
Turn the dial „TIME“ counter-clockwise fully to the left to set the shortest power-up time.
Turn the dial „LUX“ clockwise fully to the right to the sun symbol (only then the PIR sensor is
ready for operation also by daylight).
Switch off the mains voltage, if you have not already done so (then wait for 30 seconds until
the PIR sensor in the motion detector adjusts to the background temperature; now it is ready
for operation).
Pass through the detection area of the PIR sensor. If the PIR sensor detects temperature
change in the detection area, it switches the connected device for approx. 10 seconds on
and then off again.
If new motion is detected during the on-time, the on-time duration starts once again,
and the consumer stays switched on.
Maintenance and cleaning
The product is maintenance-free. Repair or maintenance work must be carried out by a
specialist.
Before cleaning switch off the mains voltage of the motion detector.
You can use a clean, dry, soft cloth for cleaning. In case of heavier soiling, you can moisten
the cloth with clean water.
Do not use abrasive cleaning agents, cleaning alcohol or other chemical solutions, since
these could damage the housing or even impair operation.
Disposal
Electronic devices are recyclable material and do not belong in the household was-
te. Dispose of the unserviceable product in accordance with the relevant statutory
regulations.
Technical data
Operating voltage .................................220 - 240 V/AC, 50 Hz
Internal power consumption .................<0.8 W
Switching power ...................................2000 W (ohmic load)
..............................................................1000 W (inductive load)
Devices with mainly resistive load are, e.g., light bulbs, heaters, etc.
Powered devices with inductive load are, e.g., engines, control gears, conventional
transformers, energy-saving bulbs, different LED lighting products etc.
Switch type ...........................................Relay, single-pole
Protection class ....................................II
Installation site ...................................... Only in dry enclosed rooms
Detection angle .....................................360°
PIR range .............................................max. approx. 6 m at ambient temperature < +24 °C
Duty cycle .............................................adjustable, 10 s (±3 s) to 15 min (±2 min)
Ambient brightness ............................... adjustable, 3 to 2000 lux
Recommended installation height ........2.4 - 4 m
Ambient conditions ............................... Temperature -20 °C to +40 °C, air humidity <93%
relative, non-condensing
Dimensions ........................................... 115 x 24 mm (Ø x H)