c) DMX Operation
EachDMXdeviceinaDMXchainrequiresaso-calledDMXstartingaddresstobeclearlyidentiedbythe
controller. This DMX starting address defines the first DMX channel to which the device responds. The
remaining control channels come after this first DMX channel (DMX starting address).
Thedevicerequires3DMXchannels.
Setting the DMX starting address
Set the desired DMX start address in the menu item DMX512 (see menu overview) with the button UP or
DOWN.
The following table provides information about the eects of the settings on the individual DMX channels.
DMX channel DMX Value Function
1 000-127 Fog emission o
128-255 Fog emission on
2 000-255 Fan speed 0-100 %
3 000-255 Fog volume setting 0-100 %
10. Handling
• Neverconnectthemainsplugtoamainssocketimmediatelyafterthedevicehasbeentakenfromacold
to a warm environment. The resulting condensation may destroy the device.
Allow the device to reach room temperature before connecting it. Wait until the condensation has eva-
porated.
• Neverpullthemainsplugfromthemainssocketbythecable.Onlypullitfromthemainssocketbythe
intended grip areas.
• Unplugthemainsadapterfromthemainssocketafteruse.
• Disconnectthemainsplugfromthemainssocketduringthunderstormsforreasonsofsafety.
• Nevertouchthedeviceinoperationorrightafterwards,becausethisareaheatsupstronglyparticularly
in the area of the fog exit opening. There is a danger of burns.
• Neverusecontaminatedfogliquids.Closethetankandthestoragecontainerforyourfogliquidimmedi-
ately after filling.
• Alwaysemptythetankbeforetransportingthedeviceorifyouarenotusingitforalongerperiod.
• Useonlywater-basedfogliquid.Suitablefogliquidsarelistedinthe„TechnicalData“section.