User manual
25
b) Manual Operation
In manual operation, the hazer can be operated via the button at the device.
• PushthebuttonFUNCTIONtogettothemenuandselectthedesiredmenuitem.
• SetthedesiredvalueswiththebuttonsUPorDOWN.
Menu Overview
INTERVAL Setting of the pause duration between the fog emissions in timed operation
DURATION Settingtheclosuredurationintimedoperation
DMX512 Setting the DMX start address for DMX mode
VOLUME Settingthefogvolume
FANSPEED Setting of the fan speed
Button function at the device
FUNCTION Selectionofthemenuitemtobeset
UP Value adjustment upwards
DOWN Valueadjustmentdownwards
TIMER Interval mode (setting of the shot and break duration takes place via the
menuitemsINTERVALandDURATION)
START/STOP Permanentoperationon/o
MANUAL Manual mode (fog emission takes place while the button is pushed)
OnceaDMXsignalispending,manualmodeisdeactivatedandthebuttonsTIMER,START/STOP
and MANUAL are locked.
Iftheintervaldurationintimedoperationissetveryshort(<20s),itispossiblethatfogliquidleft
in the fog nozzle is still being evaporated during the fog phase. This may make it impossible to
clearly recognise any fog break.