Acceptance test (in case of industrial/public use):
Before first use and after any significant modifications, the installation (including the electrical
connections) must be inspected by an ocial expert.
Ayearlyinspectionbyanexpertisrequired.
At least every 4 years, an acceptance test must be carried out by an expert.
• Setupthedeviceunderobservationoftheabovesafetynotes.
• Alternatively,thedevicecanalsobeattachedwiththemountingbracket.
• Alwaysobservehorizontalsetupforthis.
8. Connection
a) Connection of a DMX Controller
Only connect the device to a DMX controller with a DMX-512 protocol.
• ConnecttheconnectionDMXINwiththeoutputoftheDMXcontroller.
• UseascreenedXLRcableforthis.Thecontrollermusthave3freecontrolchannels.
• ConnectDMXOUTwiththeDMXinputofthesubsequentdevice(ifpresent).
• IfthehazeristhelastortheonlydeviceintheDMXchain,insertaplugwitha120ohm/0.25Wtermina-
tingresistorintotheDMXOUTsocket(betweenPin2andPin3).
Pin assignment of the DMX connection: Pin1 = earth / Pin2 = (-) / Pin3 = (+).