Explanation differential loops:
Differential loops means that you can connect NC or NO contacts here.
NC = normally closed = opener = the switching contact opens in the case of an alarm
NO = normally open = closer = the switching contact closes in the case of an alarm
Example of the connection of an NC contact sensor and an NO contact sensor:
Ensure that the connection resistance of 2.2 kOhm is connected not to the alarm control centre
but as close as possible to the sensor end.
Connection NC contact sensor:
This diagram provides an example of how sensors with NC contacts are
2,2 kOhm
NC NC
NCNC
are attached. You can connect several sensors with NC contacts to
each alarm loop.
Connection NO contact sensor:
This diagram provides an example of how sensors with NO contacts are
2,2 kOhm
NO
NO
attached. In this case you can also connect several sensors.