Information
30
(1)(2)(3)
7
8
• Use the 8 mm open-ended spanner (2) to remove
the nozzle (1). While you loosen the nozzle (in a
counterclockwise direction) lock the nozzle holder
with the adjustable spanner (3).
• Hold the nozzle with a pair of pliers and remove the
lament residues from the nozzle with the tweezers.
The extruder must not be twisted during nozzle cleaning. The nozzle must
never be turned when it has been cooled down since the plastic tube (see
image on the right) may break otherwise.
If you only want to clean the nozzle, skip steps from 9 to 14 regarding
cleaning the plastic tube and continue with step 15.
9
(4)
(3)
10
• Switch the 3D printer off.
• Unplug the power cable.
• Let the 3D printer cool down to room temperature.
• Lock the nozzle holder with the adjustable spanner (3).
Use a pair of pliers (4) to carefully pull out the plastic
tube in the direction of the arrow.