Remove both grub screws at the nozzle holder.
Carefully pull the thermistor and the heating rod out of
the nozzle holder.
Dispose the damaged thermistor with the heater.
1
2
13
1
2
14
Insert the new thermistor (1) into the large opening of
the nozzle holder (
1
).
Make sure that the end of the thermistor is aligned with
the nozzle holder.
Insert the grub screw into the tapped hole and tighten
it (
2
).
Insert the heating rod (2) into the small opening of the
nozzle holder (
1
).
Insert the grub screw into the tapped hole and tighten
it (
2
).