Installation site
a) General
• There should be no lights near the power outlet to prevent malfunction.
• The twilight sensor needs to be fully exposed and shall not be covered in any way.
• The arrow on the rating plate must face upward.
b) Indoor use
• The wall power outlet to which you connect the product must be located in an
indoorspacewithawindowinorderforthetwilightsensortodierentiatebetween
night and day.
• However, the power outlet should not be located directly next to the window to
avoid direct sunlight.
c) Outdoor use
Toensuretheproduct‘ssplashproofrating,youmustfulllthefollowing:
• Plug the product into an outdoor splash-proof power outlet.
• The power plug of the electric appliance you wish to connect to the product must
also be splash proof.
• Close the cover when no electric appliance is connected to the product.
Operation
• Turnotheelectricapplianceyouwishtoconnect.
• Plug the electric appliance into the power outlet on the product.
• Plug the product into a common household power outlet.
• Switch on the electric appliance.
• Select the desired mode using the set wheel. The arrow above the set wheel points
at the selected mode.
• To disconnect the electric appliance from the product, rst turn o the electric
appliance. Then unplug the product from the power outlet. Now you may unplug the
electric appliance from the product.
Some commercially available power adapters may not be connected to the
product due to its design.
Mode overview
Mode Function
OFF Theconnectedelectricapplianceisoconstantly.
ON The connected electric appliance is on constantly.
2Hrs
These modes allow you to manually shorten the switch-on time to 2, 4,
6, or 8 hours. The electric appliance turns on automatically in increasing
darkness.Unliketwilightmode,theproductturnsoautomaticallywhen
the countdown elapses.
4Hrs
6Hrs
8Hrs
DUSK-
DAWN
Twilight mode: The electric appliance turns on automatically in increasing
darkness. The electric appliance turns o automatically in increasing
light.
Ifyouselectadierentmodewhileaprogramisactive,theactiveprogram
is interrupted and replaced by the selected mode immediately.
If countdown mode is active and the ambient brightness increases, the
electricappliancewillturnobeforethecountdownelapses.
The most recently selected mode repeats daily.
LED status light
• The LED status light lights up constantly when the product‘s power outlet is
activated.
• The LED status light goes out when the product‘s power outlet is deactivated.
Maintenance and cleaning
• This product does not require maintenance. There are no user-serviceable
parts inside the product. Therefore, do never open/dismantle the product. Have
maintenanceandrepairsdonebyqualiedexpertsorrepairshopsonly.
• Do not use any aggressive cleaning agents, rubbing alcohol or other chemical
solutions as they can cause damage to the housing and malfunctioning.
• Never submerge the product in water or other liquids.
• Never point any water jet, such as that of a high-pressure cleaner, at the product.
• Disconnect the product from the power outlet and from the connected electric
appliance before cleaning.
• Tocleantheproduct,adry,softandcleanclothissucient.Donotapplytoomuch
pressure to the housing to prevent scratching.
• You can use a long-haired, soft and clean brush and a vacuum cleaner to remove
dust.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the
relevant statutory regulations.
Youthusfullyourstatutoryobligationsandcontributetotheprotectionof
the environment.
Technical data
Operating voltage................................230 V/AC, 50 Hz
Connected load ...................................max. 1000 W
Output current .....................................5 A
Protection type ....................................IP44
Operating conditions ..........................-10 to +55 ºC, 0 – 90 % RH
Storage conditions..............................-10 to +55 ºC, 0 – 90 % RH
Dimensions (W x H x D)......................60 x 130 x 39 mm (without plug)
Weight ...................................................180 g