Interval Mode:
• Press the yellow TIMER (9) button on the remote control.
• The device now emits fog time-controlled and the yellow indicator LED is lit.
• Set the desired interval time using the INTERVAL (8) controller.
• The device will produce fog for the set time and then pause. Then the described interval starts over.
• To deactivate interval operation, push the yellow TIMER (9) button on the remote control again.
DMX mode:
• Each DMX device in a DMX chain requires an assigned DMX channel to be clearly targeted by the con
-
troller.
• Such DMX channel is defined by the DIP switches 1-9 (1) on the rear of the device. Each DIP switch is
assigned a value. The total of the assigned values then defines the assigned DMX channel.
The DIP-switch 10 has no function.
• The values of the individual DIP switches 1-9 can be taken from the table below. If a switch is in the „ON“
position, it is activated, while in the „OFF“ position it is deactivated.
DIP switches DMX channel
1 1
2 2
3 4
4 8
5 16
6 32
7 64
8 128
9 256
Example:
DIP switches 1, 3 and 5 are set to „ON“, all other switches are set to „OFF“.
DMX channel = 1 + 4 + 16 = 21
• The amount of fog is smoothly adjusted via the DMX value of the set DMX channel.
Value „0“ > No fog emission
Value „255“ > Maximum fog emission
• When a DMX controller is connected, operation via the supplied remote control is not possible.