User manual
43
13. Maintenance
Regularly check the technical safety of the eect beamer, e.g. for damage to the mains cable or the casing.
If you have reason to believe that the device can no longer be operated safely, disconnect it immediately
and make sure it is not operated unintentionally. Pull the mains plug from the mains socket!
It can be assumed that safe operation is no longer possible if:
• thedeviceisvisiblydamaged
• thedeviceisnolongerworking
• thedevicehasbeenstoredunderunfavourableconditionsforanextendedperiodoftimeor
• thedevicehasbeensubjectedtoheavystressduringtransport
Always observe the following safety instructions before cleaning or servicing the eect beamer:
Live components may be exposed if covers are opened or components are removed.
The device must be disconnected from all power sources before any servicing or repair work is
carried out.
Capacitors inside the device may still carry voltage even though they have been disconnected
from all power sources.
Only qualified experts familiar with the hazards involved and the relevant regulations must per-
form repairs.
a) Cleaning
The outside of the eect light should only be cleaned with a soft, dry cloth or brush.
Never use any aggressive cleaning agents or chemical solutions as these may damage the surface of the
casing.
b) Fuse Replacement
If it becomes necessary to replace a fuse, make sure that only fuses of the prescribed type and nominal
current are used (see "Technical Data").
Never repair fuses or bridge the fuse holder.
• Unplugthemainsplugfromthemainssocketanddisconnectthelow-voltagecablefromthePOWERIN
mains connection of the device.
• Usingasuitablescrewdriver,carefullyopenthefuseholderwiththefaultyfusenexttothePOWERIN
mains connection.
• Removethedefectivefuseandreplaceitbyanewfuseoftheindicatedtype.
• CarefullypushthefuseholderwiththenewfusebackintoitspositionatthePOWERINmainsconnection
of the device.
• Afterthis,youcanreconnectthedevicetothemainsandtakeitintooperation.