Datasheet
R01DS0041EJ0150 Rev.1.50 Page 107 of 221
Oct 18, 2013
RX210 Group 5. Electrical Characteristics
Note 1. Supply current values do not include output charge/discharge current from all pins. The values apply when internal pull-up MOSs
are in the off state.
Note 2. Clock supply to the peripheral functions is stopped. This does not include BGO operation. The clock source is PLL and the VCO
oscillation frequency is 64 MHz. BCLK, FCLK, and PCLK are set to divided by 64.
Note 3. Clock supply to the peripheral functions is stopped. This does not include BGO operation. The clock source is HOCO and the
oscillation frequency is 40 MHz. BCLK, FCLK, and PCLK are set to divided by 64.
Note 4. Clocks are supplied to the peripheral functions. This does not include BGO operation. The clock source is PLL and the VCO
oscillation frequency is 64 MHz. BCLK, FCLK, and PCLK are ICLK divided by 1.
Note 5. Clocks are supplied to the peripheral functions. This does not include BGO operation. The clock source is HOCO and the
oscillation frequency is 40 MHz. BCLK, FCLK, and PCLK are ICLK divided by 1.
Note 6. This is the increase if data is programmed to or erasing from the ROM or E2 DataFlash during program execution.
Note 7. Clock supply to the peripheral functions is stopped. This does not include BGO operation. The clock source is HOCO and the
oscillation frequency is 32 MHz. BCLK, FCLK, and PCLK are set to divided by 64.
Note 8. Clocks are supplied to the peripheral functions. This does not include BGO operation. The clock source is HOCO and the
oscillation frequency is 32 MHz. BCLK, FCLK, and PCLK are ICLK divided by 1.
Note 9. Clock supply to the peripheral functions is stopped. This does not include BGO operation. The clock source is the sub oscillation
circuit. BCLK, FCLK, and PCLK are set to divided by 64.
Note 10.Clocks are supplied to the peripheral functions. This does not include BGO operation. The clock source is the sub oscillation
circuit. BCLK, FCLK, and PCLK are ICLK divided by 1.
Note 11.Value when the main clock continues oscillating at 12.5 MHz.
Supply
current*
1
Low-speed
operating mode
1
Normal
operating mode
No peripheral
operation*
7
ICLK = 8 MHz I
CC
2—mA
ICLK = 4 MHz 1.6 —
ICLK = 2 MHz 1.5 —
All peripheral
operation:
Normal*
8
ICLK = 8 MHz 6 —
ICLK = 4 MHz 3.8 —
ICLK = 2 MHz 2.8 —
All peripheral
operation: Max.*
8
ICLK = 8 MHz — 12
ICLK = 4 MHz — —
ICLK = 2 MHz — —
Sleep mode No peripheral
operation
ICLK = 8 MHz 1.5 —
ICLK = 4 MHz 1.4 —
ICLK = 2 MHz 1.3 —
All peripheral
operation:
Normal
ICLK = 8 MHz 3.6 —
ICLK = 4 MHz 2.7 —
ICLK = 2 MHz 2.2 —
All-module clock stop mode ICLK = 8 MHz 1.4 —
ICLK = 4 MHz 1.3 —
ICLK = 2 MHz 1.2 —
Low-speed
operating mode
2
Normal
operating mode
No peripheral
operation*
9
ICLK = 32 kHz 0.021 —
All peripheral
operation:
Normal*
10
ICLK = 32 kHz 0.05 —
All peripheral
operation:
Max.*
10
ICLK = 32 kHz — 3*
11
Sleep mode No peripheral
operation
ICLK = 32 kHz 0.017 —
All peripheral
operation:
Normal
ICLK = 32 kHz 0.034 —
All-module clock stop mode 0.016 —
Item Symbol Typ. Max. Unit
Test