To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding. Renesas Electronics website: http://www.renesas.
Notice 1. 2. 3. 4. 5. 6. 7. All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm the latest product information with a Renesas Electronics sales office.
User’s Manual H8/36024, H8/36049 Group Expansion I/O Board for E6000 Emulator User’s Manual HS36024EIO61HE Renesas Microcomputer Development Environment System H8 Family / H8/300H Tiny Series Rev.1.0 2003.
Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage.
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this emulator product. • KEEP the user's manual handy for future reference. Do not attempt to use the emulator product until you fully understand its mechanism. Emulator Product: Throughout this document, the term "emulator product" shall be defined as the following products produced only by Renesas Technology Corp. excluding all subsidiary products.
LIMITED WARRANTY Renesas warrants its emulator products to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas, at its option, will repair or replace any emulator products returned intact to the factory, transportation charges prepaid, which Renesas, upon inspection, determine to be defective in material and/or workmanship. The foregoing shall constitute the sole remedy for any breach of Renesas's warranty.
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state.
SAFETY PAGE READ FIRST • READ this user's manual before using this emulator product. • KEEP the user's manual handy for future reference. Do not attempt to use the emulator product until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000 emulator and user system before connecting or disconnecting any CABLES or PARTS. 3.
Preface Thank you for purchasing this H8/36024, H8/36049 group expansion I/O board (HS36024EIO61H; hereinafter referred to as the expansion I/O board) for the H8/36024, H8/36049 group E6000 emulator. The expansion I/O board enables user systems for Renesas's original microcomputer H8/36024, H8/36049 group to be developed using an H8/36024, H8/36049 group E6000 emulator (HS3664EPI61H; hereinafter referred to as the emulator).
Contents Section 1 1.1 1.2 1.3 1.4 Overview ..........................................................................................1 Environment Conditions.................................................................................................... 1 Supported MCUs and User System Interface Cables ........................................................ 2 Operating Voltage and Frequency Specifications ............................................................. 3 Components ....................
Section 1 Overview The H8/36024, H8/36049 group E6000 expansion I/O board (hereinafter referred to as the expansion I/O board) is an efficient software and hardware development support tool for application systems using channel 3 of Renesas's original microcomputers H8/36024, H8/36049 group SCI3 (Serial Communication Interface 3). The expansion I/O board should be used with H8/36024, H8/36049 group E6000 emulator station (HS3664EPI61H: hereinafter referred to as the emulator). 1.
1.2 Supported MCUs and User System Interface Cables Table 1.2 shows the correspondence between the MCUs and the user system interface cables supported by the E6000. H8/36024, H8/36049 group: Table 1.2 H8/36024, H8/36049 group MCUs and User System Interface Cable No.
1.3 Operating Voltage and Frequency Specifications Table 1.3 shows the MCU operating voltage and frequency specifications supported by the E6000. If the E6000 is used in an environment that exceeds the operating voltage range and operating frequency range guaranteed for the MCU operation, normal emulator operation is not guaranteed. Table 1.3 Operating Voltage and Frequency Specifications No. MCU Types Operating Voltage (V) Operating Frequency (φ) (MHz) 1 H8/36024 Group 3.0-5.
1.4 Components Figure 1.1 shows the HS36024EIO61H expansion I/O board appearance, and table 1.4 lists the components of the expansion I/O board. Please make sure you have all of these components when unpacking. E60 OR 0 0 LAT MU 00 E E 6 E 0 ABL T R IN E C CE RFA USE Figure 1.1 HS36024EIO61H Expansion I/O Board Table 1.4 HS36024EIO61H Components No.
Section 2 Connection Procedures WARNING Always switch OFF the user system and the emulator product before the EXPANSION I/O BOARD or USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on each side is correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system, the emulator product, the user system interface cable, and the expansion board, or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 2.
2.2 Using Emulator with Connecting User System through User System Interface Cable CAUTION When connecting or removing the user system interface cable, apply force only in the direction suitable for connection or removal, while making sure not to bend or twist the cable or connectors. Otherwise, the cables or connectors will be damaged. 1. Make sure the emulator and the user system are turned off. 2.
Emulator station 0 00 E6 [1] Expansion I/O board E60 00 EM TO ULA R T R IN USE LE CAB ACE ERF 00 E6 0 [2] Cable body connector CTS screws (M3 x 6 mm) User system interface cable Figure 2.
Section 3 User System Interface Switches, protection circuits, and termination circuits are provided for the H8/36024, H8/36049 SCI3_3 of the expansion I/O board. Signals are connected to the user system interface cable with the protection circuit. Figure 3.1 shows user system interface circuit. E6000 (HS3664EPI61H) HS36024EIO61H Vcc 47 kΩ H8/3664 Evaluation chip FPGA Levelconversion IC 47 Ω P12, P56, P57 Figure 3.
Section 4 Notice WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. This expansion I/O board is specifically designed for the HS3664EPI61H. Do not use this expansion I/O board with any other emulator station. 2.
H8/36024, H8/36049 Group Expansion I/O Board for E6000 Emulator User's Manual Publication Date: Rev.1.00, December 19, 2003 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. 2003 Renesas Technology Corp. All rights reserved. Printed in Japan.
H8/36024, H8/36049 Group Expansion I/O Board for E6000 Emulator User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan REJ10B0095-0100H