11 
2.6  Resulting Dimensions after Connecting User System Interface Board 
The resulting dimensions, after connecting the user system interface board to the user system, are 
shown in figure 7. 
 Unit: mm
Tolerance: ±1.0 mm
35.6
16.0
57.6
User system
EV-chip board
IC socket 
(IC149-120-043-B51
manufactured by 
YAMAICHI ELECTRONICS Co., Ltd.)
56.5
56.5
45.0
45.0
SPACER (φ5.8)
Figure 7 Resulting Dimensions after Connecting User System Interface Board 