14.4 Operation of Low-Voltage Detector
The low-voltage detector can be used in the following two modes.
Used as reset
Compares the supply voltage (V
DD) and detection voltage (VLVI), and generates an internal reset signal when
V
DD < VLVI, and releases internal reset when VDD VLVI.
Used as interrupt
Compares the supply voltage (V
DD) and detection voltage (VLVI), and generates an interrupt signal (INTLVI)
when V
DD < VLVI.
The operation is set as follows.
(1) When used as reset
When starting operation
<1> Mask the LVI interrupt (LVIMK = 1).
<2> Set the detection voltage using bits 3 to 0 (LVIS3 to LVIS0) of the low-voltage detection level select
register (LVIS).
<3> Set bit 7 (LVION) of LVIM to 1 (enables LVI operation).
<4> Use software to instigate a wait of at least 0.2 ms.
<5> Wait until “supply voltage (V
DD) detection voltage (VLVI)” at bit 0 (LVIF) of LVIM is confirmed.
<6> Set bit 1 (LVIMD) of LVIM to 1 (generates internal reset signal when supply voltage (V
DD) < detection
voltage (V
LVI)).
Figure 14-4 shows the timing of generating the internal reset signal of the low-voltage detector. Numbers <1>
to <6> in this figure correspond to <1> to <6> above.
Cautions 1. <1> must always be executed. When LVIMK = 0, an interrupt may occur immediately
after the processing in <3>.
2. If supply voltage (V
DD) detection voltage (VLVI) when LVIMD is set to 1, an internal reset
signal is not generated.
When stopping operation
Either of the following procedures must be executed.
When using 8-bit memory manipulation instruction: Write 00H to LVIM.
When using 1-bit memory manipulation instruction: Clear LVIMD to 0 and LVION to 0 in that order.