Datasheet
78K0/Ix2 CHAPTER 28 ELECTRICAL SPECIFICATIONS
R01UH0010EJ0500 Rev.5.00 698
Feb 28, 2012
Caution The pins mounted depend on the product. Refer to Caution 2 at the beginning of this chapter.
(T
A = 40 to +105C, 2.7 V VDD 5.5 V, AVREF VDD, VSS = AVSS = 0 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Watchdog timer
operating current
Note 1
I
WDT VDD = 5.0 V
In 30 kHz internal low-speed oscillation
clock operation
0.28 0.35
A
TMH1 operating
current
Note 2
I
TMH VDD = 5.0 V
When using the 30 kHz internal low-speed
oscillation clock as the count clock
0.35 2
A
LVI operating current
Note 3
I
LVI 9 18
A
High-speed
mode 1
AV
REF = VDD = 5.0 V 1.72 3.2 mA
High-speed
mode 2
AV
REF = VDD = 3.0 V 0.72 1.6 mA
A/D converter
operating current
Note 4
I
ADC
During
conversion
at maximum
speed
Normal mode AV
REF = VDD = 5.0 V 0.86 1.9 mA
PGA operating 1.2 mA
AVREF = VDD = 5.0 V 263 380
A
Operational amplifier
operating current
Note 5
I
AMP
Operational amplifier operating
AV
REF = VDD = 3.0 V 232 321
A
AVREF = VDD = 5.0 V 240
A
When internal reference
voltage is not used and
one comparator channel is
operating
AV
REF = VDD = 3.0 V 200
A
AVREF = VDD = 5.0 V 300
A
Comparator operating
current
Note 6
I
CMP
When internal reference
voltage is used and
one comparator channel is
operating
AV
REF = VDD = 3.0 V 240
A
Reset current IDDrst
After reset
(RESET pull-up resistor
current + leakage current)
AV
REF = VDD = 5.0 V 35 100
A
Notes 1. Current flowing only to the watchdog timer (including the operating current of the 30 kHz internal oscillator).
The current value of the 78K0/Ix2 microcontrollers is the sum of I
DD1, IDD2 or IDD3 and IWDT when the watchdog
timer operates.
2. Current flowing only to the 8-bits timer H1. The current value of the 78K0/Ix2 microcontrollers is the sum of
I
DD1, IDD2 or IDD3 and ITWH when the 8-bits timer H1 operates (When using the 30 kHz internal low-speed
oscillation clock as the count clock).
3. Current flowing only to the LVI circuit. The current value of the 78K0/Ix2 microcontrollers is the sum of I
DD1,
I
DD2 or IDD3 and ILVI when the LVI circuit operates.
4. Current flowing only to the A/D converter (AV
REF). The current value of the 78K0/Ix2 microcontrollers is the
sum of I
DD1 or IDD2 and IADC when the A/D converter operates in an operation mode or the HALT mode.
5. Current flowing only to the operational amplifier (AV
REF). The current value of the 78K0/Ix2 microcontrollers is
the sum of IDD1 or IDD2 and IAMP when the operational amplifier operates in an operation mode or the HALT
mode.
6. Current flowing only to the comparator (AV
REF). The current value of the 78K0/Ix2 microcontrollers is the sum
of IDD1 or IDD2 and ICMP when the comparator operates in an operation mode or the HALT mode.