Datasheet
78K0/Ix2 CHAPTER 11 A/D CONVERTER
R01UH0010EJ0500 Rev.5.00 391
Feb 28, 2012
Figure 11-18. A/D Conversion Operation
ANIn
A/D conversion is started
Note 1
Rewriting ADS ADCS = 0
ANIn
ANIn ANIn ANIm
ANIn ANIm ANIm
Stopped
Conversion result
immediately before
is retained
A/D conversion
A/D conversion
result register
Note 2
INTAD
Conversion is stopped
Conversion result immediately
before is retained
Notes 1. Software trigger mode: A/D conversion is started by setting (1) ADCS.
Timer trigger mode: A/D conversion is started when a timer trigger signal (TMX0 or TMX1 output) is
detected after ADCS is set (1).
2. Software trigger mode: ADCR, ADCRH, ADCRL registers
Timer trigger mode: ADCRX0, ADCRX0L registers (TMX0 synchronization)
ADCRX1, ADCRX1L registers (TMX1 synchronization)
Remarks 1. n = 0 to 8 (it depends on products)
2. m = 0 to 8 (it depends on products)