Datasheet

78K0/Kx2-L CHAPTER 28 ELECTRICAL SPECIFICATIONS
R01UH0028EJ0400 Rev.4.00 765
Sep 27, 2010
Caution The pins mounted depend on the product. Refer to Caution 2 at the beginning of this chapter.
(6) Supply Voltage Rise Time
(T
A = 40 to +85°C, VSS = 0 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Maximum time to rise to 1.8 V (VDD (MIN.))
Note
(V
DD: 0 V 1.8 V)
t
PUP1
LVI default start function stopped is
set (LVISTART (Option Byte) = 0),
when RESET input is not used
3.6 ms
Maximum time to rise to 1.8 V (VDD (MIN.))
Note
(releasing RESET input V
DD: 1.8 V)
t
PUP2
LVI default start function stopped is
set (LVISTART (Option Byte) = 0),
when RESET input is used
1.9 ms
Note Make sure to raise the power supply in a shorter time than this.
Supply Voltage Rise Time Timing
When RESET pin input is not used
When RESET pin input is used (when external reset is
released by the RESET pin, after POC has been released)
1.8 V
0 V
POC i
nternal
signal
t
PUP1
Supply voltage
(V
DD
)
Time
1.8 V
t
PUP2
0 V
POC i
nternal
signal
RESET pin
Internal reset
signal
Supply voltage
(V
DD
)
Time