Datasheet

78K0/Kx2-L CHAPTER 28 ELECTRICAL SPECIFICATIONS
R01UH0028EJ0400 Rev.4.00 751
Sep 27, 2010
Caution The pins mounted depend on the product. Refer to Caution 2 at the beginning of this chapter.
DC Characteristics (8/8)
(T
A = 40 to +85°C, 1.8 V VDD 5.5 V, AVREF VDD, VSS = AVSS = 0 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Real-time counter
operating current
Note 1
I
RTC VDD = 3.0 V 0.15 1
μ
A
Watchdog timer
operating current
Note 2
I
WDT VDD = 3.0 V
In 30 kHz internal low-speed oscillation
clock operation
0.28 0.35
μ
A
TMH1 operating
current
Note 3
I
TMH VDD = 3.0 V
When using the 30 kHz internal low-speed
oscillation clock as the count clock
0.35 1.5
μ
A
LVI operating
current
Note 4
I
LVI 9 18
μ
A
High-speed
mode 1
AV
REF = VDD = 5.0 V 1.72 3.2
mA
High-speed
mode 2
AV
REF = VDD = 3.0 V 0.72 1.6
mA
Normal mode AVREF = VDD = 5.0 V 0.86 1.9
mA
A/D converter
operating current
Note 5
I
ADC
During
conversion
at maximum
speed
Low-voltage
mode
AV
REF = VDD = 3.0 V 0.37 0.8
mA
PGA operating 1.2 mA
AVREF = VDD = 5.0 V 263 380
μ
A
Operational amplifier 0
operating
AV
REF = VDD = 3.0 V 232 321
μ
A
VDD = 5.0 V 263 380
μ
A
Operational amplifier
operating current
Note 6
I
AMP
Operational amplifier 1
operating
V
DD = 3.0 V 232 321
μ
A
Reset current IDDrst
After reset
(RESET pull-up resistor
current + leakage current)
AV
REF = VDD = 5.0 V 35 100
μ
A
Notes 1. Current flowing only to the real-time counter. The current value of the 78K0/Kx2-L microcontrollers is the sum
of I
DD1, IDD2 or IDD3 and IRTC when the real-time counter operates.
2. Current flowing only to the watchdog timer (including the operating current of the 30 kHz internal oscillator).
The current value of the 78K0/Kx2-L microcontrollers is the sum of I
DD1, IDD2 or IDD3 and IWDT when the
watchdog timer operates.
3. Current flowing only to the 8-bits timer H1. The current value of the 78K0/Kx2-L microcontrollers is the sum of
I
DD1, IDD2 or IDD3 and ITWH when the 8-bits timer H1 operates (When using the 30 kHz internal low-speed
oscillation clock as the count clock).
4. Current flowing only to the LVI circuit. The current value of the 78K0/Kx2-L microcontrollers is the sum of I
DD1,
I
DD2 or IDD3 and ILVI when the LVI circuit operates.
5. Current flowing only to the A/D converter (AVREF). The current value of the 78K0/Kx2-L microcontrollers is the
sum of I
DD1 or IDD2 and IADC when the A/D converter operates in an operation mode or the HALT mode.
6. Current flowing only to the operational amplifier (AV
REF or VDD). The current value of the 78K0/Kx2-L
microcontrollers is the sum of I
DD1 or IDD2 and IAMP when the operational amplifier operates in an operation
mode or the HALT mode.