CHAPTER 22 LOW-VOLTAGE DETECTOR
User’s Manual U18698EJ1V0UD
490
22.4.1 When used as reset
(1) When detecting level of supply voltage (V
DD)
When starting operation
<1> Mask the LVI interrupt (LVIMK = 1).
<2> Clear bit 2 (LVISEL) of the low-voltage detection register (LVIM) to 0 (detects level of supply voltage
(V
DD)) (default value).
<3> Set the detection voltage using bits 3 to 0 (LVIS3 to LVIS0) of the low-voltage detection level selection
register (LVIS).
<4> Set bit 7 (LVION) of LVIM to 1 (enables LVI operation).
<5> Use software to wait for an operation stabilization time (10
μ
s (MAX.)).
<6> Wait until it is checked that (supply voltage (VDD) detection voltage (VLVI)) by bit 0 (LVIF) of LVIM.
<7> Set bit 1 (LVIMD) of LVIM to 1 (generates reset when the level is detected).
Figure 22-5 shows the timing of the internal reset signal generated by the low-voltage detector. The numbers
in this timing chart correspond to <1> to <7> above.
Cautions 1. <1> must always be executed. When LVIMK = 0, an interrupt may occur immediately
after the processing in <4>.
2. If supply voltage (V
DD) detection voltage (VLVI) when LVIMD is set to 1, an internal reset
signal is not generated.
When stopping operation
Either of the following procedures must be executed.
When using 8-bit memory manipulation instruction:
Write 00H to LVIM.
When using 1-bit memory manipulation instruction:
Clear LVIMD to 0 and then LVION to 0.