Datasheet

CHAPTER 9 REAL-TIME COUNTER
User’s Manual U18698EJ1V0UD
275
(16) Alarm week register (ALARMWW)
This register is used to set date of alarm.
ALARMWW can be set by an 8-bit memory manipulation instruction.
Reset signal generation clears this register to 00H.
Caution Set a decimal value of 00 to 23, 01 to 12, or 21 to 32 to this register in BCD code. If a value
outside the range is set, the alarm is not detected.
Figure 9-17. Format of Alarm Week Register (ALARMWW)
Address: FF88H After reset: 00H R/W
Symbol 7 6 5 4 3 2 1 0
ALARMWW 0 WW6 WW5 WW4 WW3 WW2 WW1 WW0
Here is an example of setting the alarm.
Day 12-Hour Display 24-Hour Display Time of Alarm
Sunday
W
W
0
Monday
W
W
1
Tuesday
W
W
2
Wednesday
W
W
3
Thursday
W
W
4
Friday
W
W
5
Saturday
W
W
6
Hour
10
Hour
1
Minute
10
Minute
1
Hour
10
Hour
1
Minute
10
Minute
1
Every day, 0:00 a.m. 1 1 1 1 1 1 1 1 2 0 0 0 0 0 0
Every day, 1:30 a.m. 1 1 1 1 1 1 1 0 1 3 0 0 1 3 0
Every day, 11:59 a.m. 1 1 1 1 1 1 1 1 1 5 9 1 1 5 9
Monday through
Friday, 0:00 p.m.
0 1 1 1 1 1 0 3 2 0 0 1 2 0 0
Sunday, 1:30 p.m. 1 0 0 0 0 0 0 2 1 3 0 1 3 3 0
Monday, Wednesday,
Friday, 11:59 p.m.
0 1 0 1 0 1 0 3 1 5 9 2 3 5 9