Datasheet

CHAPTER 7 8-BIT TIMER/EVENT COUNTERS 50, 51, AND 52
User’s Manual U18698EJ1V0UD
233
<When starting operation>
00H 01H 02H
TM52
TMIF52
FFH 00H 01H FFH 00H 01H
0000H 0000H 0000H
TM00
0000H 0000H 0000H 0000H 0001H 0001H
when timer operation is started The timer does not count up
upon the first overflow of TM52.
The timer counts up upon second
and subsequent overflows.
<Overflow of higher timer>
FFH 00H 01H
T
M52
FFH 00H 01H FFH 00H 01H
FFFFH 0000H 0000H
T
M00
0000H 0001H 0001H 0001H 0002H 0002H
Overflow The timer counts up as normal
upon an overflow of TM00.