Datasheet
CHAPTER 5 CLOCK GENERATOR
User’s Manual U18698EJ1V0UD
119
Figure 5-9. Format of Internal High-speed Oscillation Trimming Register (HIOTRM)
Address: FF30H After reset: 10H R/W
Symbol 7 6 5 4 3 2 1 0
HIOTRM 0 0 0 TTRM4 TTRM3 TTRM2 TTRM1 TTRM0
Clock correction value (Target)
(2.7 V ≤ V
DD ≤ 5.5 V)
TTRM4 TTRM3 TTRM2 TTRM1 TTRM0
MIN. TYP. MAX.
0 0 0 0 0 TBD
−4.88%
TBD
0 0 0 0 1 TBD
−4.62%
TBD
0 0 0 1 0 TBD
−4.33%
TBD
0 0 0 1 1 TBD
−4.03%
TBD
0 0 1 0 0 TBD
−3.73%
TBD
0 0 1 0 1 TBD
−3.43%
TBD
0 0 1 1 0 TBD
−3.13%
TBD
0 0 1 1 1 TBD
−2.83%
TBD
0 1 0 0 0 TBD
−2.53%
TBD
0 1 0 0 1 TBD
−2.22%
TBD
0 1 0 1 0 TBD
−1.91%
TBD
0 1 0 1 1 TBD
−1.60%
TBD
0 1 1 0 0 TBD
−1.28%
TBD
0 1 1 0 1 TBD
−0.96%
TBD
0 1 1 1 0 TBD
−0.64%
TBD
0 1 1 1 1 TBD
−0.32%
TBD
1 0 0 0 0
±0% (default)
1 0 0 0 1 TBD +0.32% TBD
1 0 0 1 0 TBD +0.65% TBD
1 0 0 1 1 TBD +0.98% TBD
1 0 1 0 0 TBD +1.31% TBD
1 0 1 0 1 TBD +1.64% TBD
1 0 1 1 0 TBD +1.98% TBD
1 0 1 1 1 TBD +2.32% TBD
1 1 0 0 0 TBD +2.66% TBD
1 1 0 0 1 TBD +3.00% TBD
1 1 0 1 0 TBD +3.34% TBD
1 1 0 1 1 TBD +3.69% TBD
1 1 1 0 0 TBD +4.04% TBD
1 1 1 0 1 TBD +4.39% TBD
1 1 1 1 0 TBD +4.74% TBD
1 1 1 1 1 TBD +5.10% TBD
Caution The internal high-speed oscillation frequency will increase in speed if the HIOTRM register
value is incremented above a specific value, and will decrease in speed if decremented below
that specific value. A reversal, such that the frequency decreases in speed by incrementing the
value, or increases in speed by decrementing the value, will not occur.