(b) Write
Set ABTCLR Automatic block transmission engine clear request bit
0 The automatic block transmission engine is in idle status or under operation.
1
Request to clear the automatic block transmission engine. After the automatic block transmission
engine has been cleared, automatic block transmission is started from message buffer 0 by setting
the ABTTRG bit to 1.
Set ABTTRG Clear ABTTRG Automatic block transmission start bit
0 1 Request to stop automatic block transmission.
1 0 Request to start automatic block transmission.
Other than above No change in ABTTRG bit.
Caution Even if the ABTTRG bit is set (1), transmission is not immediately executed, depending on the
situation such as when a message is received from another node or when a message other
than the ABT message (message buffers 8 to 31) is transmitted.
Even if the ABTTRG bit is cleared (0), transmission is not terminated midway. If transmission
is under execution, it is continued until completed (regardless of whether transmission is
successful or fails).