• Transfer at valley when valley interrupt is set
Because the register is transferred at the transfer timing of the valley interrupt, a symmetrical triangular wave
is output.
Figure 11-35. Rewriting TAB1CCR1 Register (TAB1OPT1.TAB1ICE Bit = 1, TAB1OPT1.TAB1IOE Bit = 1,
TAB1OPT1.TAB1ID4 to TAB1OPT1.TAB1ID0 Bits = 00001)
16-bit
counter
Transfer
timing
TAB1CCR1
register
CCR1 buffer
register
TOAB1T1
pin output
i i
r
ik
Transfer at
valley interrupt
Transfer at
valley interrupt
r
k
kk
i
INTTAB1CC0
signal
INTTAB1OV
signal
Remark : Culled interrupt
(d) Rewriting TAB1OPT1 register
Because a new interrupt culling value is transferred when the value of the interrupt culling counter matches the
value of the 16-bit counter, the next interrupt and those that follow occur at the set interval.