Datasheet

V850ES/JG3-H, V850ES/JH3-H CHAPTER 11 MOTOR CONTROL FUNCTION
R01UH0042EJ0500 Rev.5.00 Page 626 of 1513
Aug 12, 2011
Transfer at valley when valley interrupt is set
Because the register is transferred at the transfer timing of the valley interrupt, a symmetrical triangular wave
is output.
Figure 11-35. Rewriting TAB1CCR1 Register (TAB1OPT1.TAB1ICE Bit = 1, TAB1OPT1.TAB1IOE Bit = 1,
TAB1OPT1.TAB1ID4 to TAB1OPT1.TAB1ID0 Bits = 00001)
16-bit
counter
Transfer
timing
TAB1CCR1
register
CCR1 buffer
register
TOAB1T1
pin output
i i
r
ik
Transfer at
valley interrupt
Transfer at
valley interrupt
r
k
kk
i
INTTAB1CC0
signal
INTTAB1OV
signal
Remark : Culled interrupt
(d) Rewriting TAB1OPT1 register
Because a new interrupt culling value is transferred when the value of the interrupt culling counter matches the
value of the 16-bit counter, the next interrupt and those that follow occur at the set interval.
For details of rewriting the TAB1OPT1 register, see 11.4.3 Interrupt culling function.