Datasheet

V850ES/JG3-H, V850ES/JH3-H CHAPTER 11 MOTOR CONTROL FUNCTION
R01UH0042EJ0500 Rev.5.00 Page 583 of 1513
Aug 12, 2011
(2/2)
TAB1AT3
Note
0
1
A/D trigger output control 3
Disable output of A/D trigger signal (TABTADT0) for INTTAA4CC1 interrupt.
Enable output of A/D trigger signal (TABTADT0) for INTRAA4CC1 interrupt.
TAB1AT2
Note
0
1
A/D trigger output control 2
Disable output of A/D trigger signal (TABTADT0) for INTTAA4CC0 interrupt.
Enable output of A/D trigger signal (TABTADT0) for INTTAA4CC0 interrupt.
TAB1AT1
Note
0
1
A/D trigger output control 1
Disable output of A/D trigger signal (TABTADT0) for INTTAB1CC0
(crest interrupt).
Enable output of A/D trigger signal (TABTADT0) for INTTAB1CC0
(crest interrupt).
TAB1AT0
Note
0
1
A/D trigger output control 0
Disable output of A/D trigger signal (TABTADT0) for INTTAB1OV
(valley interrupt).
Enable output of A/D trigger signal (TABTADT0) for INTTAB1OV
(valley interrupt).
TAB1ATM3
0
1
TAB1ATM3 mode selection
Output A/D trigger signal (TABTADT0) for INTTAA4CC1 interrupt while
dead-time counter is counting up.
Output A/D trigger signal (TABTADT0) for INTTAA4CC1 interrupt while
dead-time counter is counting down.
TAB1ATM2
0
1
TAB1ATM2 mode selection
Output A/D trigger signal (TABTADT0) for INTTAA4CC0 interrupt while
dead-time counter is counting up.
Output A/D trigger signal (TABTADT0) for INTTAA4CC0 interrupt while
dead-time counter is counting down.
Note For the setting of the TAB1AT3 to TAB1AT0 bits, see CHAPTER 15 A/D CONVERTER.