Care must be exercised in processing the overflow flag when two capture registers are used. First, an example
of incorrect processing is shown below.
Example of incorrect processing when two capture registers are used
FFFFH
16-bit counter
0000H
TT0CE bit
TIT00 pin input
TT0CCR0 register
TIT01 pin input
TT0CCR1 register
INTTT0OV signal
TT0OVF bit
D
00
D
01
D
10
D
11
D
10
<1> <2> <3> <4>
D
00
D
11
D
01
The following problem may occur when two pulse widths are measured in the free-running timer mode.
<1> Read the TT0CCR0 register (setting of the default value of the TIT00 pin input).
<2> Read the TT0CCR1 register (setting of the default value of the TIT01 pin input).
<3> Read the TT0CCR0 register.
Read the overflow flag. If the overflow flag is 1, clear it to 0.
Because the overflow flag is 1, the pulse width can be calculated by (10000H + D
01 − D00).
<4> Read the TT0CCR1 register.
Read the overflow flag. Because the flag is cleared in <3>, 0 is read.
Because the overflow flag is 0, the pulse width can be calculated by (D
11 − D10) (incorrect).
When two capture registers are used, and if the overflow flag is cleared to 0 by one capture register, the other
capture register may not obtain the correct pulse width.
Use software when using two capture registers. An example of how to use software is shown below.