Datasheet

V850ES/JG3-H, V850ES/JH3-H CHAPTER 33 ELECTRICAL SPECIFICATIONS
R01UH0042EJ0500 Rev.5.00 Page 1420 of 1513
Aug 12, 2011
33.6 Data Retention Characteristics
(1) In STOP mode
(T
A = 40 to +85°C, VDD = EVDD = UVDD = AVREF0 = AVREF1, VSS = AVSS = 0 V, CL = 50 pF)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Data retention voltage VDDDR STOP mode (all functions
stopped)
1.9 3.6 V
Data retention current IDDDR STOP mode (all functions
stopped), V
DDDR = 2.0 V
10 90
μ
A
Supply voltage rise time tRVD 200
μ
s
Supply voltage fall time tFVD 200
μ
s
Supply voltage retention time tHVD After STOP mode setting 0 ms
STOP release signal input time tDREL After VDD reaches 2.85 V (MIN.) 0 ms
Data retention input voltage, high VIHDR VDD = EVDD = UVDD = VDDDR 0.9VDDDR VDDDR V
Data retention input voltage, low VILDR VDD = EVDD = UVDD = VDDDR 0 0.1VDDDR V
Caution Shifting to STOP mode and restoring from STOP mode must be performed within the rated operating
range.
t
DREL
t
HVD
t
FVD
t
RVD
STOP release signal inputSTOP mode setting
V
DDDR
V
IHDR
V
IHDR
V
ILDR
V
DD
/EV
DD
/UV
DD
RESET (input)
STOP mode release
interrupt (NMI, etc.)
(Released by falling edge)
STOP mode release
interrupt (NMI, etc.)
(Released by rising edge)
Operating voltage lower limit