Datasheet

V850ES/JG3-H, V850ES/JH3-H CHAPTER 30 REGULATOR
R01UH0042EJ0500 Rev.5.00 Page 1354 of 1513
Aug 12, 2011
30.2 Operation
The regulators of the V850ES/JG3-H and V850ES/JH3-H always operate in any mode (normal operation mode, HALT
mode, IDLE1 mode, IDLE2 mode, STOP mode, subclock operation mode, sub IDLE mode, or during reset).
Be sure to connect a capacitor (4.7
μ
F (recommended value)) to the REGC pin
Note
to stabilize the regulator output.
A diagram of the regulator pin connection method is shown below.
Note There are two REGC pins.
Figure 30-2. REGC Pin Connection
REG
V
DD
V
SS
REGC
Input voltage
2.85 to 3.6 V
Voltage supply to oscillator/internal logic
4.7 F
(recommended
value)
μ
Caution The V850ES/JG3-H and V850ES/JH3-H have two regulators. Therefore, connect each of the
two REGC pins to a capacitor.