21.9.5 Processing after power application
The processing to be performed after power application differs depending on the configuration of the system. One
example is given below.
Figure 21-31. Example of Processing After Power Application/Power Failure (1/3)
(a) Processing after power application (1/2)
Yes
Resume detected?
No
START START
Controlling port
Note 2
Pull-up processing of
D+ inactive
Note 1
Pull-up processing
of D+ active
Note 1
Connection
Controlling port
Note 2
BUSRST = 1 (UF0IS0)
DFLT = 1 (UF0MODS)
Initialization of request
data register
Initialization of request data
register
: See Figure 21-15 Initialization
Settings of Request Data Register.
: See Figure 21-15 Initialization
Settings of Request Data Register.
(a)
Notes 1. Use one general-purpose port pin for the signal that controls switching of the pull-up resistor of the
USB bus.
2. The input mode or control mode of the general-purpose port pin allocated in Note 1 may be selected
as the default value. Note the active level of pull-up processing of D+ on power application.
Remark : Processing by hardware