V850ES/JG3 CHAPTER 29 ELECTRICAL SPECIFICATIONS
R01UH0015EJ0300 Rev.3.00 Page 776 of 870
Sep 30, 2010
AC Characteristics
AC Test Input Measurement Points (V
DD, AVREF0, AVREF1, EVDD)
V
DD
0 V
V
IH
V
IL
V
IH
V
IL
Measurement points
AC Test Output Measurement Points
V
OH
V
OL
V
OH
V
OL
Measurement points
Load Conditions
DUT
(Device under
measurement)
C
L = 50 pF
Caution If the load capacitance exceeds 50 pF due to the circuit configuration, bring the load
capacitance of the device to 50 pF or less by inserting a buffer or by some other means.