(5) When arbitration loss occurs due to stop condition during data transfer
ST AD6 to AD0 R/W ACK D7 to Dn SP
S1 Δ2
S1: IICSn register = 1000X110B
Δ 2: IICSn register = 01000001B
Remarks 1. S: Always generated
Δ: Generated only when SPIEn bit = 1
X: don’t care
2. Dn = D6 to D0
n = 0 to 2