Datasheet
V850ES/JG3 CHAPTER 16 3-WIRE VARIABLE-LENGTH SERIAL I/O (CSIB)
R01UH0015EJ0300 Rev.3.00 Page 508 of 870
Sep 30, 2010
16.6.7 Continuous transfer mode (master mode, transmission mode)
MSB first (CBnCTL0.CBnDIR bit = 0), communication type 1 (CBnCTL1.CBnCKP and CBnCTL1.CBnDAP bits = 00),
communication clock (fCCLK) = fXX/2 (CBnCTL1.CBnCKS2 to CBnCTL1.CBnCKS0 bits = 000), transfer data length = 8 bits
(CBnCTL2.CBnCL3 to CBnCTL2.CBnCL0 bits = 0000)
(1) Operation flow
START
(1), (2), (3)
(4), (8)
(5)
(11)
No (7)
Transmission
completed?
END
Yes
CBnCTL1 register ← 00H
CBnCTL2 register ← 00H
CBnCTL0 register ← C3H
Write CBnTX register
Start transmission
CBnCTL0 ← 00H
No
(6), (9)
INTCBnT interrupt
generated?
Yes
No
(10)
Yes
CBnTSF bit = 0?
(CBnSTR register)
Remarks 1. The broken lines indicate the hardware processing.
2. The numbers in this figure correspond to the processing numbers in (2) Operation timing.
3. n = 0 to 4