Datasheet
V850ES/JG3 CHAPTER 16 3-WIRE VARIABLE-LENGTH SERIAL I/O (CSIB)
R01UH0015EJ0300 Rev.3.00 Page 493 of 870
Sep 30, 2010
(a) Transfer data length change function
The CSIBn transfer data length can be set in 1-bit units between 8 and 16 bits using the CBnCTL2.CBnCL3 to
CBnCTL2.CBnCL0 bits.
When the transfer bit length is set to a value other than 16 bits, set the data to the CBnTX or CBnRX register
starting from the LSB, regardless of whether the transfer start bit is the MSB or LSB. Any data can be set for
the higher bits that are not used, but the receive data becomes 0 following serial transfer.
(i) Transfer bit length = 10 bits, MSB first
15 10 9 0
SOBn
SIBn
Insertion of 0
(ii) Transfer bit length = 12 bits, LSB first
0
SOBn
111215
SIBn