Datasheet

V850ES/JG3 CHAPTER 14 D/A CONVERTER
R01UH0015EJ0300 Rev.3.00 Page 444 of 870
Sep 30, 2010
(2) D/A conversion value setting registers 0, 1 (DA0CS0, DA0CS1)
The DA0CS0 and DA0CS1 registers set the analog voltage value output to the ANO0 and ANO1 pins.
These registers can be read or written in 8-bit units.
Reset sets these registers to 00H.
DA0CSn7DA0CSn DA0CSn6 DA0CSn5 DA0CSn4 DA0CSn3 DA0CSn2 DA0CSn1 DA0CSn0
After reset: 00H R/W Address: DA0CS0 FFFFF280H, DA0CS1 FFFFF281H
Caution In the real-time output mode (DA0M.DA0MDn bit = 1), set the DA0CSn register before the
INTTP2CC0/INTTP3CC0 signals are generated. D/A conversion starts when the
INTTP2CC0/INTTP3CC0 signals are generated.
Remark n = 0, 1