Datasheet
V850ES/JG3 CHAPTER 13 A/D CONVERTER
R01UH0015EJ0300 Rev.3.00 Page 428 of 870
Sep 30, 2010
Figure 13-7. Timing Example of One-Shot Scan Mode Operation (ADA0S Register = 03H)
(a) Timing example
A/D conversion
Data 1
(ANI0)
Data 2
(ANI1)
Data 3
(ANI2)
Data 4
(ANI3)
Data 1
(ANI0)
Data 2
(ANI1)
Data 3
(ANI2)
Data 4
(ANI3)
ADA0CRn
INTAD
Conversion start
Set ADA0CE bit = 1
Conversion end
ANI3
ANI0
ANI1
ANI2
Data 1
Data 2
Data 3
Data 4
(b) Block diagram
A/D converter
ADA0CRn registerAnalog input pin
ANI0
ANI1
ANI2
ANI3
ANI4
ANI5
ANI9
ANI10
ANI11
.
.
.
.
ADA0CR0
ADA0CR1
ADA0CR2
ADA0CR3
ADA0CR4
ADA0CR5
ADA0CR9
ADA0CR10
ADA0CR11
.
.
.