Datasheet

V850ES/JG3 CHAPTER 13 A/D CONVERTER
R01UH0015EJ0300 Rev.3.00 Page 416 of 870
Sep 30, 2010
(4) A/D converter channel specification register 0 (ADA0S)
The ADA0S register specifies the pin that inputs the analog voltage to be converted into a digital signal.
This register can be read or written in 8-bit or 1-bit units.
Reset sets this register to 00H.
0ADA0S 0 0 0 ADA0S3 ADA0S2 ADA0S1 ADA0S0
After reset: 00H R/W Address: FFFFF202H
ANI0
ANI1
ANI2
ANI3
ANI4
ANI5
ANI6
ANI7
ANI8
ANI9
ANI10
ANI11
Setting prohibited
Setting prohibited
Setting prohibited
Setting prohibited
ANI0
ANI0, ANI1
ANI0 to ANI2
ANI0 to ANI3
ANI0 to ANI4
ANI0 to ANI5
ANI0 to ANI6
ANI0 to ANI7
ANI0 to ANI8
ANI0 to ANI9
ANI0 to ANI10
ANI0 to ANI11
Setting prohibited
Setting prohibited
Setting prohibited
Setting prohibited
ADA0S3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
ADA0S2
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
ADA0S1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
ADA0S0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Select mode Scan mode
Cautions 1. When writing data to the ADA0S register in the following modes, stop the A/D
conversion by clearing the AD0M0.ADA0CE bit to 0. After the data is written to the
register, enable the A/D conversion again by setting the ADA0CE bit to 1.
Normal conversion mode
One-shot select mode/one-shot scan mode in high-speed conversion mode
2. Be sure to clear bits 7 to 4 to “0”.