Datasheet
V850ES/JG3 CHAPTER 10 WATCH TIMER FUNCTIONS
R01UH0015EJ0300 Rev.3.00 Page 384 of 870
Sep 30, 2010
CHAPTER 10 WATCH TIMER FUNCTIONS
10.1 Functions
The watch timer has the following functions.
• Watch timer: An interrupt request signal (INTWT) is generated at intervals of 0.5 or 0.25 seconds by using the
main clock or subclock.
• Interval timer: An interrupt request signal (INTWTI) is generated at set intervals.
The watch timer and interval timer functions can be used at the same time.