V850ES/JG3 CHAPTRER 8 16-BIT TIMER/EVENT COUNTER Q (TMQ)
R01UH0015EJ0300 Rev.3.00 Page 362 of 870
Sep 30, 2010
(c) Processing of overflow when two or more capture registers are used
Care must be exercised in processing the overflow flag when two capture registers are used. First, an example
of incorrect processing is shown below.
Example of incorrect processing when two or more capture registers are used
FFFFH
16-bit counter
0000H
TQ0CE bit
TIQ00 pin input
TQ0CCR0 register
TIQ01 pin input
TQ0CCR1 register
INTTQ0OV signal
TQ0OVF bit
D
00
D
01
D
10
D
11
D
10
<1> <2> <3> <4>
D
00
D
11
D
01
The following problem may occur when two pulse widths are measured in the free-running timer mode.
<1> Read the TQ0CCR0 register (setting of the default value of the TIQ00 pin input).
<2> Read the TQ0CCR1 register (setting of the default value of the TIQ01 pin input).
<3> Read the TQ0CCR0 register.
Read the overflow flag. If the overflow flag is 1, clear it to 0.
Because the overflow flag is 1, the pulse width can be calculated by (10000H + D
01 − D00).
<4> Read the TQ0CCR1 register.
Read the overflow flag. Because the flag is cleared in <3>, 0 is read.
Because the overflow flag is 0, the pulse width can be calculated by (D
11 − D10) (incorrect).
When two capture registers are used, and if the overflow flag is cleared to 0 by one capture register, the other
capture register may not obtain the correct pulse width.
Use software when using two capture registers. An example of how to use software is shown below.