V850ES/JG3 CHAPTRER 8 16-BIT TIMER/EVENT COUNTER Q (TMQ)
R01UH0015EJ0300 Rev.3.00 Page 361 of 870
Sep 30, 2010
When executing pulse width measurement in the free-running timer mode, four pulse widths can be measured
with one channel.
To measure a pulse width, the pulse width can be calculated by reading the value of the TQ0CCRm register in
synchronization with the INTTQ0CCm signal, and calculating the difference between the read value and the
previously read value.
Remark m = 0 to 3