H8/3337Y Series, H8/3334 Series TQFP-80C User System Interface Cable (HS3337ECN61H) for E6000 Emulator User’s Manual HS3337ECN61HE(C)
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
Preface Thank you for purchasing the E6000 emulator for the Renesas’s original microprocessor H8/300 series. The HS3337ECN61H is a user system interface cable that connects an H8/300 series E6000 emulator (HS3008EPI60H; hereinafter referred to as the emulator) to the IC socket for a TQFP80C package (package code: TFP-80C) for the H8/3337Y series or H8/3334 series MCU on the user system.
Contents Preface Section 1 .........................................................................................................i Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................4 2.1 2.2 2.3 2.4 2.5 Connecting User System Interface Cable to Emulator Station .........................................
Section 1 Configuration CAUTION Use an IC149-080-058-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-80C package IC socket on the user system. Figure 1 shows the configuration of the HS3337ECN61H user system interface cable for the TFP-80C package.
To emulator station Cable body Screws (M2.6 x 12 mm) with flat washers (for fastening cable head) Screws (M2.
Table 1 lists the HS3337ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS3337ECN61H Components No. Component Quantity Remarks Includes flat cable 1 Cable body 1 2 Cable head 1 3 IC socket 1 For the TFP-80C package 4 Socket cover 1 For installing an TFP-80C-packaged MCU 5 Screws (M2.6 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system, follow the instructions below. 2.2.
2.2.4 Fastening Cable Head CAUTION 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.294 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder. 3.
Screws (M2.6 x 12 mm), flat washer Cable head Pin 1 IC socket (IC149-080-058-B51 manufactured by YAMAICHI ELECTRONICS Co. Ltd.
2.2.5 Connecting Cable Body to Cable Head Connect the cable body to the cable head.
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the dimensions for the recommended mount pad (footprint) for the user system with an IC socket for an TFP-80C package (IC149-080-058-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. 15.10 (min.) 11.80 (max.) 0.30 0.05 0.50 0.50 0.05 0.05 0.05 0.05 0.50 19 = 9.50 19 = 9.50 0.
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Unit: mm Tolerance: –0.
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head User system IC socket (IC149-080-058-B51 manufactured by YAMAICHI ELECTRONICS Co. Ltd.) Unit: mm Tolerance: –0.
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.294 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Screws (M2.6 x 8 mm) with flat washers Socket cover MCU Pin 1 IC socket (IC149-080-058-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.
Section 4 Verifying Operation 1. When using the H8/300 series E6000 emulator (HS3008EPI60H), turn on the emulator according to the procedures described in the H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 1. 3.
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS3008EPI60H emulator. Do not use this cable with any other emulator station. 4.