User`s manual

SuperH Family E10A-USB Emulator Section 2 Software Specifications when Using the Emulator
REJ10J1941-0300 Rev. 3.00 Page 43 of 46
Aug 25, 2010
Notes: 1. In the non-realtime trace mode of the AUD trace, normal counting cannot be performed
because the generation state of the stall or the execution cycle is changed.
2. For SH72546RFCC, SH72531FCC, or SH72531RFCC do not set measurement items
for the cache-miss counts, cacheable area, or non-cacheable area.
3. Even when [Exception/interrupt counts (EA)] is selected as the measurement item, no
trap-instruction exception caused by TRAPA instructions will be counted.
(2) Displaying the Measured Result
The measured result is displayed in the [Performance Analysis] window or the
PERFORMANCE_ANALYSIS command with hexadecimal (32 bits).
Note: If a performance counter overflows as a result of measurement, “********” will be
displayed.
(3) Initializing the Measured Result
To initialize the measured result, select [Initialize] from the popup menu in the [Performance
Analysis] window or specify INIT with the PERFORMANCE_ANALYSIS command.