User`s manual

Section 2 Software Specifications when Using the Emulator SuperH Family E10A-USB Emulator
Page 40 of 46 REJ10J1941-0300 Rev. 3.00
Aug 25, 2010
(a) Specifying the Measurement Start/End Conditions
The measurement start/end conditions are specified by using Event Condition 1,2. The [Ch1,2,3]
list box of the [Combination action (Sequential or PtoP)] dialog box can be used.
Table 2.15 Measurement Period
Classification Item Description
Selection in
the [Ch1, 2, 3]
list box
Ch2 to Ch1
PA
The period from the satisfaction of the condition set in Event
Condition 2 (start condition) to the satisfaction of the condition set
in Event Condition 1 (end condition) is set as the performance
measurement period.
Ch1 to Ch2
PA
The period from the satisfaction of the condition set in Event
Condition 1 (start condition) to the satisfaction of the condition set
in Event Condition 2 (end condition) is set as the performance
measurement period.
Other than
above
The period from the start of execution of the user program to the
occurrence of a break is measured.
Figure 2.6 [Performance Analysis] Dialog Box