(1) Sequential Setting
Using the [Combination action (Sequential or PtoP)] dialog box specifies the sequential condition
and the start or end of performance measurement.
Table 2.8 Conditions to Be Set
Classification Item Description
[Ch1, 2, 3] list box Sets the sequential condition and the start or end of performance
measurement using Event Conditions 1 to 3 and 11.
Don’t care Sets no sequential condition or the start or end of
performance measurement.
Break: Ch3-2-1 Break in execution when Event Conditions 3, 2,
and 1 are satisfied in that order.
Break: Ch3-2-1,
Reset point
Break in execution when Event Conditions 3, 2,
and 1 are satisfied in that order.
Enables the reset point of Event Condition 11.
Break: Ch2-1 Break in execution when Event Conditions 2 and 1
are satisfied in that order.
Break: Ch2-1,
Reset point
Break in execution when Event Conditions 2 and 1
are satisfied in that order.
Enables the reset point.
I-Trace stop: Ch3-2-1* Halts acquisition of an internal trace when Event
Conditions 3, 2, and 1 are satisfied in that order.
I-Trace stop: Ch3-2-1,
Reset point*
Halts acquisition of an internal trace when Event
Conditions 3, 2, and 1 are satisfied in that order.
Enables the reset point.
I-Trace stop: Ch2-1* Halts acquisition of an internal trace when Event
Conditions 2 and 1 are satisfied in that order.
I-Trace stop: Ch2-1,
Reset point*
Halts acquisition of an internal trace when Event
Conditions 2 and 1 are satisfied in that order.
Enables the reset point.
Ch2 to Ch1 PA* Sets the performance measurement period during
the time from the satisfaction of the condition set in
Event Condition 2 (start condition) to the
satisfaction of the condition set in Event Condition
1 (end condition).